+86 188-6868-668
English
1U Modular Australian‑Standard Rack PDU VH‑4061
You are here: Home » Products » PDU » Australia PDU » 1U Modular Australian‑Standard Rack PDU VH‑4061
Contact HI-SUN Today

loading

1U Modular Australian‑Standard Rack PDU VH‑4061

VH‑4061 1U modular Australian‑standard rack PDU with AS/NZS 3112 Type‑I sockets. Hot‑swap configurable modules, aluminium housing, 16A 240V for Australia & New Zealand server cabinets.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Product Introduction


This Modular Australian Rack PDU is a 1U 19‑inch horizontal rack‑mount blank‑chassis power distribution platform built exclusively for Australian and New‑Zealand cabinet projects. Distinct from factory pre‑populated VH‑4063 (switched ready‑to‑run unit) and VH‑4062 (2U dual‑deck high‑density pre‑wired frame), this unit ships as an empty configurable mechanical skeleton without pre‑installed control or protection modules. System integrators hand‑pick and fit individual hot‑swap modules to exactly match tender specifications, site‑level safety requirements and budget constraints.

Equipped with native AS/NZS 3112 Type‑I Australian sockets, rated for 16A / 4000W @240VAC, built with thermally‑optimised extruded aluminium alloy and CE & RoHS compliant. It serves as a flexible hardware foundation for custom‑built power deployments for enterprise server rooms, surveillance racks and industrial automation cabinets across AU‑NZ territories.

Core positioning: Blank build‑to‑order modular chassis platform; zero pre‑loaded functions, you only procure required modules, perfect for public‑sector and enterprise tender projects requiring fully customised power‑distribution hardware.


Product Advantage


1.True Blank‑Chassis Build‑To‑Spec Foundation

Unlike most off‑the‑shelf AU‑market PDUs that ship with fixed pre‑installed features you may never utilise, VH‑4061 arrives as bare chassis. There are no pre‑loaded switches, surge devices or meters. Integrators select only the exact modules required for each tender. This eliminates unnecessary component‑cost waste, a huge advantage for large government and education bidding projects with highly variable technical requirement documents.


2. Native AS/NZS 3112 Type‑I Sockets Eliminates Adapter Risks

Genuine flat‑pin Type‑I receptacles fully comply with Australian‑New‑Zealand local electrical‑installation standards. Universal multi‑region PDUs frequently deployed in AU projects rely on clunky adapters, which create high‑resistance joints, over‑heating hazards and compliance‑audit non‑conformity. This native‑socket design removes adapter dependency for local IT and industrial hardware.


3. High‑Ambient‑Tuned Aluminium Profile For Australian Server‑Room Climate

Many on‑premise Australian server closets run at elevated ambient temperatures. One‑piece extruded aluminium delivers superior passive convection cooling compared with steel‑bodied competing units. It disperses cumulative heat generated by multiple live plug‑in modules, lowers internal hot‑spot risk, extends module service‑life and reduces static load weight placed upon cabinet mounting rails in densely‑populated racks.


4. Cross‑Family Inter‑Operable Hot‑Swap Module Ecosystem

All functional modules are mechanically interchangeable across the complete HI‑SUN Australian‑range PDU portfolio. After site deployment you can add, swap or upgrade modules without discarding the main chassis body. This lowers integrator spare‑parts stock inventory burden; the same module stock pool works for VH‑4061, VH‑4062 and VH‑4063 hardware families, simplifying warehouse‑stock management for local resellers.


5. Dual‑Orientation Mounting Suited For Diverse AU‑NZ Cabinet Brands

Adjustable side mounting lugs support both front‑facing installation and reversed rear‑feed cable routing. Australian cabinet OEMs adopt many varied internal wiring layouts; dual‑mode mounting prevents sharp cable‑bending damage and accelerates on‑site contractor assembly during multi‑rack roll‑out projects.


6. Complete Test‑Documentation Kit For Tender‑Audit & Customs Clearance

Full chassis and socket batch‑test reports are supplied with each unit, supporting import‑compliance checks and public‑sector tender‑qualification audits in Australia and New‑Zealand. OEM silkscreen private‑label marking is available for bulk‑order local‑reseller inventory programmes.


Technical Specifications

CategorySpecification
ModelVH‑4061
Form Factor1U horizontal, 19‑inch EIA standard rack‑mount
Socket StandardAS/NZS 3112 Type‑I Australian‑New‑Zealand native flat‑pin sockets
Rated Voltage220‑240VAC 50Hz
Max Rated Current16A
Max Power Output4000W
EnclosureExtruded aluminium alloy, matte silver / matte black finish optional
Overall Dimensions482.6 × 45 × 45 mm (L×W×H)
MountingAdjustable dual‑orientation mounting lugs (forward‑facing / reversed rear‑feed)
InputAustralian‑standard mains plug; optional IEC‑C14 inlet; 2‑meter power cord, customisable lengths
CertificationsCE, RoHS
Included AccessoriesM6 mounting fasteners, lock washers, chassis‑assembly instruction manual
Compatible Hot‑Swap ModulesMaster switch, overload MCB, SPD surge suppressor, digital volt‑ampere meter, dual‑USB‑A charger, RS485 environmental‑monitor module (sold separately)


Real‑World Application Scenarios & Reference Deployment Cases


1. Australian government & education tender cabinet projects: Bidding documents with highly customised power‑distribution requirement lists; select modules strictly aligned to tender technical clauses without paying for unneeded hardware.

2. Enterprise multi‑phase data‑centre expansion: Start with basic configuration, add metering / surge / monitoring modules later as rack‑equipment density grows.

3. Industrial automation cabinets across AU‑NZ sites: Mixed protection, switching and monitoring requirements for factory‑floor control‑hardware racks.

4. Large‑scale security‑surveillance rack deployments: Variable protection needs across different building zones within one multi‑site project.

5. New‑Zealand commercial‑building IT‑closet fit‑outs: Shared AS/NZS 3112 socket‑standard, for custom‑spec commercial fit‑out contracts.

6. Local reseller private‑label build‑your‑own PDU inventory: Stock blank chassis plus modular accessories to fulfil mixed‑spec customer orders without holding dozens of finished‑SKUs.

Deployment note: This is blank base chassis; all control, protection and metering modules must be ordered separately and fitted either in‑factory or during on‑site installation.


Order Information

ItemDetails
Minimum Order1 unit
CustomizationCustom‑length power‑cable, OEM logo marking, factory pre‑populated module assembly (bulk‑order only)
Production Capacity300 units / month
Lead Time7‑15 working‑days for bare blank chassis; 20‑30 working‑days for factory pre‑populated custom module builds
PackingShock‑resistant export carton
Trade TermsFOB, CFR, CIF, EXW


Frequently Asked Questions


Q: How does VH‑4061 differ from VH‑4062 and VH‑4063 Australian‑series PDUs?

A: VH‑4061 = blank 1U modular chassis (no built‑in functions, modules purchased separately for fully custom builds). VH‑4062 is a 2U dual‑deck high‑density bare chassis for high‑outlet‑count racks. VH‑4063 is factory pre‑wired switched ready‑to‑deploy finished unit for fast roll‑outs. All three share AS/NZS 3112 sockets and common hot‑swap‑module ecosystem.


Q: Are modules included inside the VH‑4061 package?

A: No. This is blank chassis only. Master‑switch, overload breakers, SPD surge protection, meters and USB‑ports are all separate‑order hot‑swap modules. You can choose factory pre‑assembly or perform on‑site fitting.


Q: Can I add or swap modules after rack‑installation?

A: Yes, hot‑swap‑compatible modules allow field‑retrofit without replacing main chassis body, supporting phased project‑function expansion.


Q: Will this chassis work for both Australian and New‑Zealand deployments?

A: Yes. AS/NZS 3112 is unified socket‑standard for both territories, the chassis and native Type‑I sockets satisfy installation norms in both markets.


Q: Is reversed rear‑feed mounting supported?

A: Yes, adjustable mounting lugs support forward‑facing or reversed rear‑feed mounting to match varied Australian and New‑Zealand cabinet‑wiring layouts.


Q: Can I get pre‑assembled chassis with selected modules from factory?

A: Yes, for bulk‑volume orders we can pre‑fit your chosen set of hot‑swap modules before shipment, removing on‑site module‑assembly labour.



Previous: 
Next: 

Contact Us

 Tel: +86-574-8726-7243 / 8818-3928
 Phone: +86-186-5829-0993
 E-mail: sale@nbhisun.net
 Add: Rm1306 Minghui bldg 666 Jinyu Road Ningbo China

Quick Links

Products

Contact HI-SUN Today

Contact HI-SUN Today
Copyright © 2026 Ningbo Hi-Sun Network Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy