+86 188-6868-668
English
1U SPD‑Protected Aluminum French Type E Rack PDU VH‑4023
You are here: Home » Products » PDU » France PDU » 1U SPD‑Protected Aluminum French Type E Rack PDU VH‑4023
Contact HI-SUN Today

loading

1U SPD‑Protected Aluminum French Type E Rack PDU VH‑4023

VH‑4023 1U aluminium rack‑mount PDU with built‑in SPD surge‑shield, six French NFC61‑314 Type E outlets and illuminated main toggle. Lightning‑defended power distributor built for French & Belgian 19‑inch server enclosures.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Product Introduction


This Factory‑Integrated SPD French Type‑E Rack PDU is a 19‑inch 1U horizontal rack‑mount power distribution unit purpose‑built for French and Belgian commercial IT deployments, where grid switching transients and indirect‑lightning surges frequently threaten sensitive rack‑housed electronics. Distinct from basic outlet‑only VH‑4021 and switch‑only VH‑4022 (without built‑in surge hardware), this unit comes off the production line with fully validated SPD surge‑suppression hardware paired with native NFC61‑314 Type‑E French‑spec outlets.

Rated 16A / 4000W @220‑250VAC, housed in extruded aluminium alloy. Rather than forcing integrators to source and fit separate third‑party surge accessories on‑site, it delivers native socket compliance plus in‑built transient‑voltage mitigation in one factory‑tested assembly. CE & RoHS compliant, it targets commercial colocation, industrial automation and surveillance cabinet projects across France, Belgium and French‑speaking EU territories.

Core positioning: Factory‑validated SPD‑integrated French‑spec rack PDU; native NFC61‑314 Type‑E outlets; removes on‑site SPD‑assembly labour risk, retains hot‑swap expansion for evolving cabinet requirements for FR‑BE tender‑grade projects.


Product Advantage


1.Factory‑Validated SPD Eliminates Field Surge‑Fit Risks

Many competing French‑market PDUs leave surge protection as an after‑market add‑on. Improper on‑site SPD wiring or poor earthing drastically lowers real‑world surge‑mitigation effectiveness. VH‑4023 completes SPD assembly, impulse‑testing and continuity checks inside factory. It absorbs grid‑switching spikes and indirect‑lightning‑coupled transients out‑of‑the‑box, shielding costly servers, storage arrays and network gear, removing human‑error risks associated with third‑party accessory fitting at customer premises.


2. Native NFC61‑314 Type‑E Socket Bank For FR‑BE Compliance Audits

Six genuine NFC61‑314 earthed Type‑E receptacles are pre‑mounted and batch‑validated. Generic multi‑purpose universal sockets or adapter‑reliant solutions often trigger non‑conformity remarks during French and Belgian site acceptance inspections. Native Type‑E geometry works directly with local equipment plugs without intermediate adaptors, simplifying tender‑project compliance review for system integrators operating in French‑language EU regions.


3. Illuminated Front‑Panel Toggle Tuned For Commercial Cabinet Servicing

Red back‑lit master power switch sits on the front faceplate. During hardware swap‑outs or scheduled cabinet maintenance, technicians execute full‑bank power isolation and verify live‑power status visually without opening deep cabinet rear sections. This improves day‑to‑day service safety for colocation suites and multi‑tenant office equipment‑rooms.


4. Thermally‑Optimised Aluminium Profile Adapted For Dense French Server Closets

One‑piece extruded‑aluminium construction dissipates cumulative heat generated by six active outlets under sustained mixed‑device loads. Compared to conventional steel‑bodied alternatives, it suppresses hot‑spot build‑up inside tightly‑packed commercial racks, slows socket‑contact ageing and lowers static weight load applied to cabinet mounting rails. Matte‑silver finish matches mainstream French‑deployed server‑rack interior aesthetics.


5. Hot‑Swap Auxiliary Bays For Phased‑Project Functional Expansion

Even though SPD and main switch are factory‑integrated, reserved modular slots remain available. As project scope evolves, technicians can add overload breakers, power‑reading meters or USB‑charging peripherals post‑commissioning. No requirement to discard the main PDU chassis; optimises total‑cost‑of‑ownership for multi‑phase office‑refit and industrial‑cabinet roll‑outs across France‑Belgium.


6. Consolidated Test‑Documentation For Local Tender‑Submission

Each unit ships with combined finished‑unit test‑reports covering both SPD performance and Type‑E socket electrical safety. Consolidated documentation eases audit‑checklist fulfilment for French‑Belgium commercial and industrial tender bids. OEM silkscreen private‑label marking can be enabled for bulk‑order local reseller stock programmes.


Deployment note: This unit delivers secondary‑level surge mitigation. Sites exposed to high‑probability direct‑lightning events still require primary‑grade lightning‑arrestor hardware upstream following French and Belgian local electrical‑installation codes.


Technical Specifications

CategorySpecification
ModelVH-4023
Form Factor1U horizontal, EIA 19‑inch rack‑mount
Built‑in HardwareFactory‑integrated SPD surge‑suppression module; red illuminated master power toggle
Socket StandardNFC61-314 Type E (French standard), 16A earthed
Output Sockets6× Type E outlets
Standard ProtectionBuilt-in SPD surge suppression module
Input Connection2m French-approved power cord; custom length available; IEC C14 inlet optional
ControlRed illuminated master power switch
Rated Voltage220–250VAC, 50/60Hz
Max Rated Current16A
Max Power Output4000W
Housing MaterialExtruded aluminum alloy
FinishMatte silver
Product SizeL×W×H=482.6×45×45mm
Mounting Length462.4mm
Case Length431mm
Mounting HardwareM6 mounting fasteners, lock nuts, adjustable installation brackets, user manual
CertificationsCE, RoHS, meets NFC61‑314 French electrical‑specifications
Custom OptionsCustom cable length, custom logo printing, functional module upgrades


Real‑World Application Scenarios & Reference Deployment Cases


1. French enterprise commercial server suites & colocation branch racks: Urban business‑park rack environments subject to frequent utility‑grid switching transients; factory‑SPD safeguards high‑value compute and storage hardware.

2. Belgium multi‑site surveillance recording cabinet deployments: Security‑system integrator projects across Wallonia and Flanders; native Type‑E sockets remove adapter‑related connection faults for continuous‑recording NVR hardware.

3. Paris‑region office‑building structured‑wiring IT closets: Multi‑tenant office equipment‑rooms, convenient front‑panel power isolation for periodic hardware‑refresh cycles.

4. French‑speaking EU industrial‑automation control enclosures: Factory‑floor PLC‑hosting racks vulnerable to plant‑equipment‑originated voltage‑spikes.

5. System‑integrator tender‑grade cabinet‑projects in France & Belgium: Public‑and‑private bidding documents specifying both surge‑protection and NFC‑compliant native French‑standard outlets.


Frequently Asked Questions


Q: Where should I pick VH‑4023 versus VH‑4021 / VH‑4022 French‑series PDUs?

A: Select VH‑4023 when your project requires factory‑built SPD surge‑defence together with native NFC61‑314 Type‑E sockets. VH‑4021 is basic outlet‑only model without switch or surge hardware; VH‑4022 provides master‑switch capability but lacks integrated SPD. All three share the same hot‑swap module ecosystem and French socket‑norm compliance.


Q: Is surge‑protection already fitted, or must I buy separate SPD accessories?

A: SPD surge‑suppression module is factory‑pre‑installed and pre‑tested. No separate surge hardware purchase or on‑site fitting work is needed for baseline transient‑overvoltage protection. For high‑risk lightning‑locations, add upstream primary‑surge‑arrestor per local electrical‑codes.


Q: Are Type‑E sockets compliant for French‑Belgium tender‑acceptance inspections?

A: Yes, receptacles adhere strictly to NFC61‑314 specifications, and combined SPD plus socket test‑documentation is supplied, supporting audit‑procedures for local commercial‑industrial bidding projects.


Q: Can I add overload‑breakers or digital power‑meters after rack‑installation?

A: Yes. Hot‑swap‑compatible auxiliary slots permit field‑retrofit of overload breakers, volt‑ampere meters and USB‑charging modules, without replacing main PDU housing.


Q: Does this PDU fit mainstream 19‑inch server racks deployed inside France and Belgium?

A: Yes, built to global EIA‑19‑inch 1U rack‑standard, adjustable mounting lugs work with most popular local cabinet OEM hardware.


Q: What precaution applies for sites with high direct‑lightning‑exposure probability?

A: On‑board SPD functions as secondary‑stage surge mitigation. Install separate upstream primary lightning‑arrestor device following French / Belgian low‑voltage installation regulations for locations with frequent direct‑lightning activity.



Previous: 
Next: 

Contact Us

 Tel: +86-574-8726-7243 / 8818-3928
 Phone: +86-186-5829-0993
 E-mail: sale@nbhisun.net
 Add: Rm1306 Minghui bldg 666 Jinyu Road Ningbo China

Quick Links

Products

Contact HI-SUN Today

Contact HI-SUN Today
Copyright © 2026 Ningbo Hi-Sun Network Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy