+86 188-6868-668
English
1U Overload‑protected Master‑switch Danish Rack PDU VH‑4086
You are here: Home » Products » PDU » Denmark PDU » 1U Overload‑protected Master‑switch Danish Rack PDU VH‑4086
Contact HI-SUN Today

loading

1U Overload‑protected Master‑switch Danish Rack PDU VH‑4086

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Product Introduction


This Master‑Switch Overload‑Protected Danish Rack PDU is a 19‑inch 1U rack‑mount power distribution unit purpose‑built for Danish managed commercial, educational and mid‑size data‑center cabinet environments. Distinct from bare‑base VH‑4084 (no built‑in control/protection) and surge‑focused VH‑4085 (factory SPD for thunder‑prone remote sites), this unit integrates illuminated master switch plus resettable over‑current cut‑off module out‑of‑factory. Native DEN(13) sockets comply with local SB 107‑2‑D1 / DK2 electrical norms, removing adapter‑dependent risks for local IT hardware.

Rated for 13A / 250VAC and built on HI‑SUN hot‑swap modular platform, CE & RoHS certified. It is optimised for indoor multi‑user cabinet environments where routine hardware maintenance and prevention of accidental overload incidents are core operational priorities. 

Core positioning: All‑in‑one factory‑integrated control + over‑current safety PDU for Danish managed indoor cabinets; native DEN(13) compliance for local tender audits; hot‑swap slots allow later addition of surge, metering or USB modules without unit replacement.


Core Product Features



1.Combined Master‑Switch + Resettable Over‑Current Safety Module

Many competing Danish commercial PDUs separate switch and overload protection: either only a simple toggle switch without overload cut‑off, or fuses requiring replacement after tripping. VH‑4086 integrates illuminated master switch and push‑button resettable overload in one front‑panel assembly. During cabinet servicing technicians can cut full‑rack power in one action; when multi‑user device loads exceed limits it trips automatically. After fault elimination operators simply press the front‑panel button for reset, no spare fuses needed on‑site.


2. Native DEN(13) Shuttered Sockets Satisfy Danish Commercial Audit Requirements

Fully compliant with SB 107‑2‑D1 / DK2 local socket norms. Universal multi‑standard sockets from third‑party vendors often fail acceptance checks for Danish education and public‑sector tenders. Genuine DEN(13) receptacles eliminate adapter‑induced over‑heating risks and help integrators smoothly pass project electrical‑safety inspection.


3. Hot‑Swap Modular Platform For Evolving Commercial‑Site Demands

Office and education‑site cabinet requirements frequently change in phases. Unlike many competing fixed‑circuit Danish PDUs whose functions are locked at manufacturing time, reserved hot‑swap auxiliary slots enable field technicians to add surge defence, power‑metering or USB‑charging modules later. There is no requirement to discard the existing PDU hardware, lowering long‑term total‑cost‑of‑ownership for multi‑phase building‑refit projects.


4. Optimised For Multi‑User Overload‑Risk Indoor Cabinet Scenarios

Educational facilities and shared commercial IT closets connect large quantities of end‑user devices, creating high risk of cumulative over‑current. This unit’s overload module is calibrated for typical Danish commercial 13A circuit conditions. Steel chassis undergoes thermal aging testing simulating fluctuating mixed loads, enhancing reliability under daily multi‑device‑connection cycles.


5. Versatile Multi‑Mode Mounting For Diverse Danish Commercial Furniture

Complete TP‑series adjustable bracket set supports standard horizontal rack mounting, vertical wall‑mount and custom cabinet installation. This suits not only standard server racks, but also retrofitted office furniture and non‑standard equipment closets common in older Danish office‑building renovations, without cabinet structural modification.


6. Complete Documentation Package For Public‑Sector Tender Submission

Each unit is shipped with full module‑level test‑reports for switch‑overload assembly plus socket safety validation documents, satisfying audit‑documentation requirements for Danish education, retail and public‑sector bidding projects. OEM silkscreen marking is available for bulk‑order local‑integrator private‑label inventory.


Real‑World Application Scenarios & Reference Deployment Cases


1. Downtown commercial‑office IT equipment closets: Copenhagen and regional business‑park server cabinets; convenient front‑panel power isolation for regular IT hardware replacement, overload defence for mixed office‑peripheral loads.

2. Educational‑institution network cabinets: School and university IT racks with large numbers of student‑connected devices; resettable overload reduces service calls caused by accidental multi‑device over‑current events.

3. Mid‑size managed data‑center cabinets: Indoor managed racks requiring local manual power isolation plus basic over‑current safety, without the extra cost of built‑in surge hardware for non‑thunder‑prone city premises.

4. Retail & hospitality back‑of‑house IT cabinets: Store and hotel equipment‑closets for POS network and surveillance hardware, supporting easy maintenance work by on‑site technical staff.

5. SME server‑rooms with periodic‑maintenance cycles: Small‑enterprise IT racks where technicians frequently swap servers and network switches, needing quick full‑bank power shut‑off capability.

6. System‑integrator turnkey commercial tender cabinet‑projects: Bidding specifications requiring native DEN(13) sockets plus combined switch and resettable overload protection.

Deployment note: This PDU delivers outlet‑level overload protection. Site design shall still comply with Danish electrical‑installation regulations for upstream distribution‑circuit protection.


Frequently Asked Questions


Q: When should I select VH‑4086 compared with VH‑4084 and VH‑4085?

A: Choose VH‑4086 for managed indoor commercial / education cabinets requiring both manual master power control and resettable overload‑current protection. VH‑4084 is baseline bare‑unit without built‑in safety‑control hardware for simple general‑purpose deployment. VH‑4085 prioritises factory SPD surge‑protection for lightning‑exposed remote wind‑farm or rural sites. All three adopt DEN(13) Danish‑standard sockets and share identical hot‑swap mechanical platform.


Q: How does the resettable overload protection operate after tripping?

A: When aggregate load exceeds rated threshold, the internal overload mechanism cuts output power automatically. After removing excess load source and confirming fault status, press the front‑panel physical push‑button to restore power; no fuse‑replacement required.


Q: Can I add surge‑protection or power‑metering modules after cabinet installation?

A: Yes. Hot‑swap architecture allows DY‑series SPD, digital‑meter and USB‑charging modules to be fitted on‑site. Module retrofit does not demand full‑rack power‑shutdown or replacement of main PDU housing.


Q: Can German Schuko plugs be inserted directly into VH‑4086 sockets?

A: No, it implements dedicated DEN(13) Danish‑standard shuttered receptacles, mechanical dimensions are not compatible with Schuko plugs. For Schuko‑spec equipment, please select our corresponding German‑standard PDU product series.


Q: Besides standard horizontal 19‑inch rack‑mount, are other installation configurations available?

A: Complete TP‑series multi‑purpose bracket set is included as‑standard, supporting vertical wall‑mount and custom‑cabinet fixing, well‑suited for office‑building renovation and non‑standard equipment‑closet deployments.


Q: Are attached documents sufficient for Danish education / commercial tender audit‑checks?

A: Yes. Each delivery includes switch‑overload‑module performance‑test‑reports and socket‑compliance documentation, satisfying typical public‑sector and commercial tender‑document‑audit criteria in Denmark.




Previous: 
Next: 

Contact Us

 Tel: +86-574-8726-7243 / 8818-3928
 Phone: +86-186-5829-0993
 E-mail: sale@nbhisun.net
 Add: Rm1306 Minghui bldg 666 Jinyu Road Ningbo China

Quick Links

Products

Contact HI-SUN Today

Contact HI-SUN Today
Copyright © 2026 Ningbo Hi-Sun Network Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy