| Availability: | |
|---|---|
| Quantity: | |
VH‑4047 is a bare‑bone blank‑base 1U rack‑mount power distribution unit built for United Kingdom market, adopting native BS1363 GBR(13) series British‑standard receptacle hardware.
No factory‑pre‑installed master switch, overload or surge‑protection components. Every functional part including indicator, switch, breaker, SPD surge unit, metering and communication modules are purchased separately and fitted via hot‑swap slots. Multiple physical orientation choices for BS1363 sockets (0° /135° /45°) are available to resolve cable‑routing bottlenecks inside compact UK server cabinets. Rated for 13A 250VAC UK mains. Compatible with comprehensive HI‑SUN functional‑module ecosystem. Holding CE & RoHS credentials, this blank‑base British PDU suits system integrators who require fully tailor‑specified power‑distribution hardware for UK enterprise data‑centres, educational sites and commercial cabinet projects.
1. Blank‑base Bare‑bone Chassis Without Pre‑installed Functional Hardware
Factory delivers pure power‑conducting skeleton only. No pre‑mounted switches, indicator lamps, surge or overload components. System integrators select and procure exactly the modules they need for each cabinet, eliminating cost for unwanted factory‑bundled features for UK bespoke tender projects.
2. Multi‑angle BS1363 British‑standard Socket Choices
Offer GBR(13) socket variants in 90°,135°,45° mounting angles. Different socket orientations optimise cable‑routing paths inside shallow or densely‑populated 19‑inch UK server racks, preventing cable squeezing and plug stress damage. Fully complies with BS1363 UK electrical requirements.
3. Complete Hot‑swap‑ready Modular Slot Layout
Reserved vacant functional cavities support live on‑site hardware retrofitting. Main power toggle switches, LED indicators, overload breakers, SPD surge suppressors, digital metering panels, USB charging and RS485 monitoring modules can be added at deployment or during later equipment upgrade phases; complete PDU disassembly is unnecessary.
4. UK‑grid‑calibrated Electrical Design
Circuit architecture optimised for mainstream United Kingdom 230V‑50Hz mains environment, furnishing consistent power supply for rack‑mounted servers, network switches, storage hardware and surveillance equipment.
5. Standard‑compliant 1U Rack‑optimised Form Factor
Strict 1U physical profile adheres to EIA‑19‑inch global rack specifications, conserving precious vertical cabinet real‑estate for high‑density hardware stacks within UK enterprise and educational machine‑rooms.
6. Full‑range TP‑series Adjustable Mounting Ecosystem
Rich portfolio of TP‑variant mounting brackets supports horizontal rack‑mount, vertical wall‑fix and special‑shape cabinet assembly, coping with diverse spatial constraints of commercial, education and industrial premises across United Kingdom.
Compared with other region‑targeted bare‑bone PDU models (Argentinian / Brazilian etc.):
1. UK‑exclusive BS1363 multi‑angle socket portfolio: Other bare‑bone platforms supply single fixed‑angle outlets only. VH‑4047 provides 90°/135°/45° BS1363 socket options to solve cable‑management pain points common in shallow UK server cabinets.
2. Mains tuning for UK 230V‑50Hz grid: Optimised for British domestic power norms, different from South‑America dual‑voltage or Southern‑Europe 220V‑50Hz tuning, perfectly matching local site acceptance check criteria for UK public‑sector tenders.
Compared with ordinary British‑market bare‑bone rack‑PDU competitors:
1. Multi‑angle genuine BS1363 socket selection: Many competing blank‑frame UK PDUs only offer one fixed socket orientation. VH‑4047 gives integrators cable‑routing flexibility by selecting different socket angles per‑project.
2. Full hot‑swap modular ecosystem: A large number of local competing bare‑bone PDUs adopt semi‑fixed circuit construction with limited expandable slots. VH‑4047 supports the complete HI‑SUN functional‑module catalogue, enabling phased upgrade without replacing main PDU housing.
3. Comprehensive adjustable‑mounting accessory supply: Majority of UK‑market competitors only supply simple fixed mounting lugs. Full TP‑series adjustable brackets are included to adapt non‑standard cabinet‑body layouts frequently‑seen in UK education and retrofit projects.
‑ Bespoke‑spec enterprise cabinet tender projects across London and major UK business hubs
‑ Phased‑deployment education‑sector server racks with future functional‑upgrade roadmaps
‑ Mixed‑requirement lab‑test environments for validating assorted PDU functional‑module combinations
‑ Special‑shallow‑depth server cabinets requiring optimised angled socket cable‑routing
‑ Public‑sector and local‑authority IT projects demanding fully non‑bundled custom PDU configuration
‑ UK export‑oriented cabinet projects requiring tailor‑built BS1363 power‑distribution set‑ups
British‑standard Socket Assembly
‑GBR(13)‑series panel‑mount receptacles;available angle variants:90°(GBR13),135°(GBR13R),45°(GBR13L), rated 13A‑250VAC, complying official BS1363 UK electrical norms.
‑Inlet plug options:GBR(13)‑01 assembled plug / GBR(13)‑02 molded BS1363 plug.
Note: VH‑4047 contains NO pre‑installed control or protection modules. All below items are separate order‑able add‑ons
Optional Field‑retrofit Modules (ordered separately)
1. Control & Indicator Parts: PS1 / PS2 power‑status LED indicators;KP‑series master illuminated switches;GZS/GZ overload‑protector units;XD‑series 1‑pole/2‑pole/3‑pole miniature circuit‑breakers (1A‑60A)
2. Safety‑protection Parts: LB leakage‑current protectors;DY‑series SPD surge‑suppression units (standard / hot‑swap, optional EMI‑filter & LED‑status indicators)
3. Metering‑monitoring Parts: DB‑series standalone ammeters, combined volt‑ampere read‑out panels, hot‑swap‑capable measuring hardware
4. Auxiliary‑peripheral Parts: DY‑40T/80T RJ signal filters;USB dual‑5V charging hardware;WL RJ45 communication port;MT RS485 multi‑parameter monitor (voltage / current / temperature / humidity)
5. Mounting‑hardware Parts: Full TP‑series adjustable metal brackets, TP‑018 complete bolt‑and‑cage‑nut fastener kit.
Q1: What socket‑angle options are offered on VH‑4047?
A: Three BS1363 socket physical orientations can be specified at order time: standard 90°, 135° reverse‑angled and 45° inclined sockets, for optimised cable‑routing in shallow UK server cabinets.
Q2: Can I fit switch, surge‑protection or metering modules onto VH‑4047 afterwards?
A: Yes. Thanks to hot‑swap modular slots, KP‑series switches, DY‑series SPD units, GZ‑series overload protectors or DB‑series metering panels can be mounted on‑site without swapping the whole PDU main‑housing.
Q3: Which mains environment does VH‑4047 adapt to?
A: It is optimised for United Kingdom local 230VAC‑50Hz power‑supply system, matching mainstream domestic and industrial grid specifications within UK territory.
Q4: Is VH‑4047 compatible with 19‑inch racks used in United Kingdom?
A: Yes. It observes EIA‑19‑inch 1U international‑rack specification, compatible with most mainstream server‑and‑network‑cabinet products widely used inside United Kingdom.
Q5: Are custom‑length cables and OEM‑silkscreen branding supported?
A: Yes. Custom‑cord‑length and OEM‑logo‑printing services are available for MOQ‑based bulk‑project‑orders. Please forward detailed requirement specifications to our sales representatives.
Q6: Are there pre‑installed switches or protection modules fitted on VH‑4047?
A: No, VH‑4047 is bare‑bone blank‑base unit with zero factory‑pre‑fitted control or protection hardware. Every functional module needs to be selected and ordered individually for your project.